NATURAL GAMMA SONDE
The Geoline digital natural gamma ray sonde
can be used on its own or in combination with
other Geoline sondes for correlation
Specifications
- Weight:3.1 kg
- Length:0.7 m
- Diameter:38 mm
- Detector (Nal):50 or 25 mm
- Max pressure:20 Mpa
- Max temperature:80 deg C

CALIPER SONDE
The caliper probe can be used on its own or in
combination with other Geoline sondes or with a second
caliper sonde to provide a low cost four arm caliper
Specifications
- Weight:4.0 kg
- Length:0.7 m
- Diameter:38 mm
- Max pressure:20 Mpa
- Max temperature:80 deg C
- Range:45 mm - 350 mm

DUAL DENSITY SONDE
This combination sonde is suitable for quantitative
formation density measurements in uncased holes.
Specifications
- Weight:18/24 kg
- Length:1.8 m
- Diameter:60 mm
- Detectors (Nal):2 x Nal crystals with 38 & 15 cm spacing
- Source requirement:Typically 100 Mci 138 Cs
- Density range:1-3 gm
- Max pressure:20 Mpa
- Max temperature:80 deg C
|
Measurements
|
Applications
|
- Long spaced density:gm/cc
- Short spaced density:gm/cc
- Natural gamma:Api
- Caliper:mm
- Borehole volume:cubic meters
|
- lithology identification
- Rock density measurement
- Bed boundary
- Ground compaction
- Location of fractures, caving zones
and cementation verification
|

NORMAL RESISTIVITY SONDE
The digital resistivity sonde
can be used on its own or in combination with
other Geoline sondes for efficient logging and correlation
Specifications
- Weight:7.0 kg
- Length:2.2 m
- Diameter:42 mm
- 64"N & 16"N
- Resistivity range:1 to 10 000 ohmm
- SP range:-2.5v to +2.5v
- Current return:Cable armour
- Measure return:Bridle electrode
- Max pressure:20 Mpa
- Max temperature:80 deg C

TEMPERATURE-CONDUCTIVITY SONDE
The Temperature-Conductivity probe can be used on its own or in
combination with other sondes
Specifications
- Weight:2.0 kg
- Length:0.7 m
- Diameter:38 mm
- Temperature range:0-80 deg C
- Accuracy:50 to 50 000 microS/cm - +/-2.5% @ 500 microS/cm
- Max pressure:20 Mpa
- Max temperature:80 deg C
- Range:45 mm - 350 mm

TECHNICAL SPECIFICATIONS
- High-speed microprocessor controlled digital communication - for efficient data acquisition
- Stacking capability - probe combinations tailored to requirements (saving time and money)
- Variable resolution - allows for measurements of up to 32-bit resolution
- Variable sampling rate - control over vertical resolution
- Down hole digital signal processing - accurate and stable calibrated measurements
- Digital communications - no loss of accuracy in cable transmission
- Microsoft Windows data acquisition software - fully compatible with industry standard
- Single board in most sondes - increased reliability, easier spares control and maintenance
- Short and long spaced density - spacing of 15 and 38 cm respectively
- Tungsten collimation - for reduced background scatter
- Three point calibration - for accurate bulk density
|